Chapter 1

Airplane General

Note: This is just a summary of the FCOM content that regularly shows up in Type Rating exams. For an overview of the systems in this chapter, check the FCOM

DIMENSIONS

  • Width: 35.79 m
  • Length: 39.5 m
  • Wingtip Radius: 22.9 m (Do not turn away from an obstacle within 7.4 m of the nose)

EMERGENCY EXIT LIGHTS

Three positions:

  • OFF: Prevents unwanted illumination and unwanted battery usage
  • ARMED: Emergency exit lights will illuminate with loss of DC Bus 1 or AC power off
  • ON

OVERWING EMERGENCY EXITS

  • 4 overwing exits automatically lock when:
    • 3 of 4 main doors are closed
    • Either engine is running
    • Ground/air logic sense airborne or both thrust levers above 53%

OXYGEN

  • Flight Crew Oxygen:
    • One oxygen bottle in the aft E&E bay, must be pressurized to 1100 psi for the first flight, 1000 psi thereafter.
    • Oxygen mask has 3 modes:
      • Emer (100% oxygen under pressure) - Use if halon is discharged in the flight deck
      • 100% (100% oxygen on demand)
      • Norm (air/oxygen mixture on demand)
  • Pax Oxygen:
    • Automatic deployment above 14,000 ft or manual deployment by the crew with the pax oxygen switch.
    • Chemical oxygen generation for approximately 12 minutes.

COCKPIT DOOR ACCESS SYSTEM

Three lights:

  • Red: Indicates the door is locked, and the lock system is operating
  • Amber: Indicates the correct code has been entered and is awaiting flight crew response
    • Flight crew can either unlock the door or deny entry
    • Without response, the flight deck door will automatically unlock
  • Green: Indicates the door automatically unlocks

Dead bolt system: Three positions:

  • Unlocked
  • Locked Key Operable
  • Locked Key Inoperable