Chapter 1
Airplane General
Note: This is just a summary of the FCOM content that regularly shows up in Type Rating exams. For an overview of the systems in this chapter, check the FCOM
DIMENSIONS
- Width: 35.79 m
- Length: 39.5 m
- Wingtip Radius: 22.9 m (Do not turn away from an obstacle within 7.4 m of the nose)
EMERGENCY EXIT LIGHTS
Three positions:
- OFF: Prevents unwanted illumination and unwanted battery usage
- ARMED: Emergency exit lights will illuminate with loss of DC Bus 1 or AC power off
- ON
OVERWING EMERGENCY EXITS
- 4 overwing exits automatically lock when:
- 3 of 4 main doors are closed
- Either engine is running
- Ground/air logic sense airborne or both thrust levers above 53%
OXYGEN
- Flight Crew Oxygen:
- One oxygen bottle in the aft E&E bay, must be pressurized to 1100 psi for the first flight, 1000 psi thereafter.
- Oxygen mask has 3 modes:
- Emer (100% oxygen under pressure) - Use if halon is discharged in the flight deck
- 100% (100% oxygen on demand)
- Norm (air/oxygen mixture on demand)
- Pax Oxygen:
- Automatic deployment above 14,000 ft or manual deployment by the crew with the pax oxygen switch.
- Chemical oxygen generation for approximately 12 minutes.
COCKPIT DOOR ACCESS SYSTEM
Three lights:
- Red: Indicates the door is locked, and the lock system is operating
- Amber: Indicates the correct code has been entered and is awaiting flight crew
response
- Flight crew can either unlock the door or deny entry
- Without response, the flight deck door will automatically unlock
- Green: Indicates the door automatically unlocks
Dead bolt system: Three positions:
- Unlocked
- Locked Key Operable
- Locked Key Inoperable