Chapter 3

Anti-Ice & Rain

Note: This is just a summary of the FCOM content that regularly shows up in Type Rating exams. For an overview of the systems in this chapter, check the FCOM

ENGINE ANTI-ICE

Engine anti-ice is taken from the 5th and 9th stages of the engine compressor, upstream of the bleed air valve. The engine anti-ice valve is electrically controlled and air pressure operated. Engine start switches must be selected CONT during engine anti-ice operation.

WING ANTI-ICE

The wing anti-ice system is a supply duct heating the three inboard slats only. The valve system is AC operated. The valves automatically close when takeoff (T/O) power is set during takeoff or when the duct temperature reaches 125°C.

PROBE HEAT

Each probe is powered from its associated AC transfer bus. In the event of a loss of all AC power, the captain's pitot probe is heated by the AC standby bus (All other probes are not heated).