Electrical
- QPQDK1 variant
If the RAT stalls, or if the aircraft is on the ground with a speed below 100kt, the emergency generation network transfers automatically to the batteries and the static inverter, and the system automatically sheds the:
✅ AC SHED ESS BUS and DC SHED ESS BUS
- QRSCN1 variant
What do you have to consider if you have to disconnect an IDG?
✅ Disconnect the IDG only when the engine is running or windmilling
- QGRPF1 variant
If the IDG is disconnected once.
✅ The IDG may be reconnected on ground only
- QHTPX1 variant
Which failure combination will trigger the EMER ELEC configuration automatically?
✅ AC BUS 1 is not electrically supplied and AC BUS 2 is not electrically supplied and Aircraft speed is greater than 100 kt
- QHXZP1 variant
How is the emergency generator powered?
✅ The ram air turbine (RAT) must be extended. This powers the blue hydraulic system, which drives the emergency generator by means of a hydraulic motor
- QSRLR1 variant
AC power can be generated by:
✅ The 3 generators or an emergency generator or a static inverter supplied by batteries
- QBAYK1 variant
How much is the power output of each engine driven generator?
✅ 90 KVA
- QHVBM1 variant
On ground with external power connected and MAINT BUS switch ON, the AC and DC GND/FLT buses are supplied by:
✅ External power directly
- QFSPN1 variant
The RAT extends automatically if
✅ AC BUS 1 and AC BUS 2 fail
- QZBQD1 variant
Which bus is not powered during EMER ELEC in flight?
✅ DC BAT BUS
- QWLWB1 variant
What would happen to the battery voltage if you switch off the main power supply (EXT PWR+APU) and leave the BAT 1 and BAT 2 pushbuttons in the AUTO position?
✅ The automatic cut-off logic would prevent the batteries from discharging completely
- QWXOC1 variant
What does the BAT check of the PNF include during Preliminary Cockpit Preparation?
✅ Check BAT 1+2 OFF, check voltage > 25.5 V
- QCMGH1 variant
Which statement concerning COMPUTER RESET / CB policy is correct?
✅ Do not pull the SFCC & ECU or EEC, EIU CBs
- QFZPC1 variant
TRIPPED C/B RE-ENGAGEMENT A FUEL PUMP C/B has tripped by itself. Which statement regarding the re-engagement is correct
✅ both answers are correct
- QCSJV1 variant
IDG FAULT light lights up amber if:
✅ The IDG oil outlet overheats or IDG oil pressure is low
- QPYVO1 variant
If both the AC BUS 1 and AC BUS 2 buses are lost and the aircraft speed is above ________, the Ram Air Turbine (RAT) extends automatically:
✅ 100 knots
- QPYSV1 variant
A Generator Control Unit (GCU) controls the output of each generator. The main function(s) of each GCU are:
✅ Control the frequency and voltage of the generator output and protect the network by controlling the associated Generator Line Contactor (GLC)
- QYGWM1 variant
If AC BUS 1 fails, the AC ESS BUS is supplied by:
✅ AC BUS 2
- QTNHT1 variant
In case of loss of all main generators, prior to RAT extension and emergency generator coupling, the emergency generation network (AC and DC power) is supplied by:
✅ The batteries via the static inverter for AC power and the batteries for DC power
- QNTJI1 variant
What happens when the GEN 1 pushbutton switch is set to the OFF position?
✅ The generator field is de-energized and line contactor opens. The fault circuit is reset
- QPTPI1 variant
The BAT FAULT light illuminates if:
✅ The charging current for the corresponding battery is outside limits
- QWHII1 variant
The aircraft has two types of C/Bs:
✅ Monitored (green), non-monitored (black)
- QNEEL1 variant
The two batteries are connected to the DC BAT BUS if they need charging. When they are fully charged the battery charge limiter:
✅ Disconnects them
- QVKFJ1 variant
On the emergency electric power panel, a fault light illuminates under the 'RAT and EMER GEN' label. What does it mean?
✅ The emergency generator is not supplying power when AC bus 1 and 2 are not powered
- QQJJQ1 variant
When the aircraft main electrical system is not powered, the battery voltage can be checked:
✅ On the electrical section of the overhead panel
- QRMVS1 variant
The AC essential bus is normally supplied by:
✅ The AC BUS 1
- QYEFU1 variant
When the aircraft speed is above ________, the static inverter is automatically activated, if nothing but the batteries are supplying electrical power to the aircraft, regardless of the BAT 1 and BAT 2 pb-sw positions.
✅ 50 knots
- QNHAU1 variant
What are the priorities in the electrical power supply of the A/C?
✅ GEN 1 and 2 over APU and over EXT PWR. External power has priority over APU generator when the EXT PWR pb switch is ON
- QEYQH1 variant
The RAT extends automatically when:
✅ The MAN ON pb on the EMER ELEC PWR panel is on AUTO, AC BUS 1 and 2 are not electrically supplied and the aircraft speed is greater than 100 kt
- QUTRR1 variant
Which statement concerning the electrical generators is correct?
✅ All answers are correct
- QJCBW1 variant
While operating in emergency electrical configuration with the landing gear extended, which of the following control laws is active?
✅ Direct law
- QOHOI1 variant
Which busses will be powered after the RAT is extended and the EMER GEN begins producing electrical power?
✅ HOT BAT busses, DC ESS, DC ESS SHED, AC ESS and AC ESS SHED
- QHRAA1 variant
During an emergency electrical configuration what happens after landing?
✅ Below 100 kt, DC BAT BUS is automatically connected to the batteries and below 50 kt the AC ESS BUS is no longer powered, leading to the loss of all display units
- QMRBG1 variant
Which statement about the IDG is correct?
✅ Pushing the IDG pb-sw for more than 3 seconds may damage the IDG disconnection mechanism
- QFYNV1 variant
The time for the ECAM to trigger the C/B TRIPPED warning for Monitored C/Bs is:
✅ 1 min
- QEPRS1 variant
The generator indications on the ECAM page are:
✅ Load (%), voltage (V) and frequency (HZ)
- QIACV1 variant
The EMERGENCY GENERATOR is driven by:
✅ By a hydraulic motor in the BLUE hydraulic system
- QBHXB1 variant
The EMERGENCY GENERATOR supplies :
✅ AC ESS BUS
- QVKGM1 variant
To disconnect the IDG press the guarded IDG DISCONNECT pb-sw for:
✅ A maximum of 3 seconds
- QINCX1 variant
If the GEN 1 LINE pb-sw is switched to OFF:
✅ AC BUS 1 channel is supplied from GEN2 through bus tie contactors. The inner tank pumps 1 are supplied directly by IDG and pump relays by DC ESS
- QBZVQ1 variant
What is the important thing to remember, to avoid damaging the disconnection mechanism of the IDG, when the IDG pb-sw will be pushed?
✅ To push the IDG pb-sw for a maximum of 3 seconds but make sure that the engine is running or windmilling
- QFMCX1 variant
After an IDG disconnection, why do you get a GALLEY SHED indication on the SD?
✅ It is a reminder that the main galleys have been shed automatically following the loss of one generator