Hyd
- QZKYI1 variant
Engine 2 powers:
✅ The yellow system pump and the green system via the PTU should green system pump fail.
- QCBAP1 variant
The yellow system comprises:
✅ One engine driven pump, one electric pump, one hand pump.
- QQTKV1 variant
The load alleviation function accumulators operate in case of high demands on:
✅ The yellow and green powered spoilers 4 + 5 and ailerons.
- QYSWC1 variant
With PTU in AUTO, the PTU automatically runs:
✅ When differential pressure between green and yellow system is more than 500 psi.
- QGUHO1 variant
With green and yellow hydraulic systems lost, manual pitch trim is:
✅ Lost.
- QYRXJ1 variant
With the green system only remaining, the auto brake is:
✅ Available
- QYFAC1 variant
With only hydraulic blue system remaining:
✅ Seven full brake applications are available.
- QHTDY1 variant
The green system operates:
✅ Reverser 1.
- QMUSN1 variant
Normal hydraulic power is provided by:
✅ Engine driven pumps for green and yellow, electric pump for blue, electric pump for yellow (ground operation only).
- QLKFV1 variant
The power transfer unit is:
✅ Reversible between green and yellow.
- QZMUB1 variant
In flight, if blue electric pump fails the blue system:
✅ Can be recovered by RAT.
- QLPGF1 variant
With both engines shutdown, how is it possible to pressurize the green system?
✅ By the yellow electric pump and the PTU.
- QYOCR1 variant
The RAT is automatically extended in case of:
✅ AC1 and AC2 unpowered
- QFXTM1 variant
On ground the blue system is pressurized when:
✅ One engine is running.
- QNBJR1 variant
Which Statement about the Ram Air Turbine (RAT) is correct?
✅ The RAT deploy automatically, if AC BUS 1 and AC BUS 2 are both lost only
- QXBZL1 variant
If BLUE system is lost, SLAT/FLAP operation is:
✅ SLAT Half Speed / FLAP Normal
- QPMWG1 variant
The priority valves operate in case of:
✅ Cuts off hydraulic power to heavy load user systems if hydraulic pressure in a system gets low
- QCFEW1 variant
In case of a system reservoir overheat, the fault light stays on:
✅ As long as the overheat lasts
- QBBZH1 variant
You get a G RSVR OVHT ECAM message. Why does the ECAM procedure ask you to switch the PTU off first?
✅ You want to stop the PTU from pressurizing the GREEN system
- QKPAY1 variant
What is the normal pressure in the hydraulic system?
✅ 3000 psi
- QWPCJ1 variant
Normal hydraulic power is provided by
✅ Engine driven pumps for GREEN and YELLOW, Electrical pump for blue, Electrical pump for YELLOW (ground operation only)
- QGGXN1 variant
You have started engine 2, but the PTU has not operated to pressurize the GREEN hydraulic system. Why not?
✅ TThe PTU will not operate until the second engine has been started.
- QUDAF1 variant
You get a G RSVR OVHT message. Why does the ECAM procedure ask you to switch the PTU off first?
✅ You want to stop the PTU from pressurizing the GREEN system.
- QCJHG1 variant
What is the normal pressure in the hydraulic system?
✅ 3000 psi
- QSWNF1 variant
During start up, when is the BLUE hydraulic system pressurized?
✅ Automatically after first engine start.
- QQCDN1 variant
With reference to the PTU, which statement is correct?
✅ The PTU enables the GREEN and YELLOW system to pressurize each other.
- QBVTX1 variant
In a case the RAT is deployed, the following statement is true:
✅ Blue hydraulic system and emergency generator are available
- QRJAH1 variant
Under which conditions does the RAT deploy automatically?
✅ AC BUS 1 and AC BUS 2 are lost
- QUJHN1 variant
In flight, if BLUE electric pump fails the BLUE system:
✅ Can be recovered by the RAT
- QJIRC1 variant
What does the RAT MAN ON Pb do?
✅ Extends the RAT, pressurizes the BLUE hydraulic system, does not couple the Emergency Generator
- QGVOW1 variant
How many source systems provide pressure to the YELLOW SYS?
✅ 4 (one electrical driven pump, one mechanical driven pump, one accumulator & PTU)
- QAIJT1 variant
If the RAT pressurizes the BLUE hydraulic system, the operating pressure is approximately ____.
✅ 2500 PSI
- QYTDM1 variant
With green hydraulic low pressure the alternate brake system has the same capabilities as normal brakes except:
✅ Autobrakes are inoperative
- QPVVF1 variant
After deploying the ram air turbine (RAT), is it possible to check its position and status?
✅ Yes, on the ECAM HYD page and in the MEMO of the upper ECAM (RAT OUT)
- QEOZU1 variant
When will normal operation of the BLUE system hydraulic pump begin?
✅ As soon as one engine is running
- QSWCF1 variant
In flight the eng 1 pump fault light illuminates amber in case of:
A reservoir low level
A reservoir overheat
A reservoir low air press
A pump low press
✅ True
- QEMPJ1 variant
The yellow system may be powered by:
✅ Engine 2 hydraulic pump - The yellow electric pump - The PTU - A hand pump when no electrical power is available to operate the cargo doors.
- QIVYO1 variant
With green hydraulic system lost, the anti skid is:
✅ Operative on the yellow hydraulic system.
- QZZPM1 variant
If blue system is lost, flap operation is:
✅ Normal.
- QVIWH1 variant
The priority valves operate in case of:
✅ Cuts off hydraulic power to heavy load user systems if hydraulic pressure in a system gets low.
- QGBYX1 variant
Each of the ______________________ systems has a fire shutoff valve in its line upstream of its engine- driven pump.
✅ The green and yellow
- QOJDN1 variant
When the RAT MAN ON PB is pressed in case of blue electric pump failure:
✅ The blue hydraulic system is pressurized by the RAT driven hydraulic pump.
- QKOGI1 variant
The hydraulic reservoirs are pressurized:
✅ From engine one or the crossbleed duct.
- QJEMA1 variant
The RAT can be restored:
✅ On the ground only.
- QBVFW1 variant
In flight the RAT may be extended:
✅ Manually or automatically.
- QWERC1 variant
Is it possible to interchange hydraulic fluid from green to yellow or yellow to green system:
✅ No.
- QLEAB1 variant
The fire shut off valve closes when:
✅ The fire PB is released out.
- QSDOE1 variant
If the green system is lost, slat operation is:
✅ Slow
- QDMQX1 variant
The green system operates:
✅ Spoilers 1 and 5.
- QVHKF1 variant
The green system operates:
✅ The left elevator.
- QMABL1 variant
The green system operates
✅ The left and the right aileron
- QQPLB1 variant
The yellow system operates:
✅ Reverser 2.
- QLAQW1 variant
On ground, with the blue electric pump PB in AUTO, the circuit is energized if:
✅ One engine is running or BLUE PUMP OVRD PB has been pressed.
- QGUQY1 variant
If blue system is lost, the slats operation is:
✅ Half speed.
- QQNXH1 variant
The blue system operates:
✅ Spoilers 3.
- QNUHS1 variant
The RAT can be extended:
✅ Manually from the overhead panel or automatically in case of loss of power to AC bus 1 and AC bus 2.
- QQYSX1 variant
The blue system operates:
✅ The left and the right aileron
- QXFSG1 variant
If yellow system is lost, the slat operation is:
✅ Normal.
- QAAKF1 variant
Can you operate a cargo door when no electrical power is available?
✅ Yes
- QCBAS1 variant
If yellow system is lost, the flap operation is:
✅ Half speed.
- QLNTR1 variant
The engine 2 fire valve is between the yellow reservoir and:
✅ The engine 2 hydraulic pump.
- QSVXP1 variant
The yellow system operates:
✅ The spoilers 2 and 4.
- QGENT1 variant
In case of single hydraulic system low press:
✅ The master caution light illuminates and the single chime sounds.
- QQKQM1 variant
With a single hydraulic system failure the flight control law is:
✅ Normal.
- QGKYC1 variant
With green hydraulic system lost:
✅ The landing gear must be extended by gravity.
- QUKGJ1 variant
With green hydraulic system lost:
✅ The NWS is operative.
- QGHUV1 variant
With the PTU running, the pressure delivered by the PTU is:
✅ 3000 psi.
- QOXAI1 variant
In case of a system reservoir overheat, the fault light stays on:
✅ As long as the overheat is detected.
- QXIJT1 variant
The green pump pressure is low (inhibited on the ground, when the engine is stopped). The FAULT light goes out, when the crew selects OFF, except during an overheat.
✅ True
- QGQIW1 variant
The blue system includes operation of:
✅ The slats.
- QYQKF1 variant
When extended in flight the RAT pressurizes:
✅ The blue system.
- QIUFQ1 variant
Which elevator does the yellow system operate:
✅ The right elevator only.
- QDJQV1 variant
During the first engine start the PTU is:
✅ Inhibited.
- QCHRF1 variant
During the second engine start the PTU is:
✅ Automatically tested.
- QRHID1 variant
What does a FAULT light in the PTU pb switch indicate?
✅ All answers are correct
- QSIDQ1 variant
What happens when the ground crew move the cargo door manual selector either to OPEN or CLOSE position (aircraft is electrically powered)?
✅ The yellow electrical pump is automatically energized, the yellow system is partly pressurized (cargo doors, engine 2 reverse and alternate braking only)
- QEXMC1 variant
Which statement about the YELLOW electrical Pump is correct?
✅ The electric pump can also pressurize the system, which allows YELLOW hydraulics to be used on the ground when the engines are stopped
- QEIML1 variant
Which conditions activate a FAULT light on the hydraulic engine driven pump Pb?
✅ Reservoir low-level / reservoir overheat / reservoir low air pressure / pump low pressure
- QLIOC1 variant
In case of an engine 1 failure at lift-off....
✅ All hydraulic systems remain fully available, only the G ENG 1 PUMP is inop
- QRJSL1 variant
What main components are powered by the yellow hydraulic system?
✅ NWS, Alternate brake system, Reverser ENG 2 and Stabilizer
- QBGTK1 variant
The power transfer unit (PTU) starts operation automatically when the differential pressure between the GREEN and the YELLOW systems is greater than ___.
✅ 500 PSI
- QJFON1 variant
When does the PTU start operating?
✅ When the differential Pressure between GREEN and YELLOW System is higher than 500 PSI
- QVXUP1 variant
How many Spoilers are still operating during YELLOW and GREEN hydraulic failure (BLUE system remaining)?
✅ 1 per wing
- QKAIR1 variant
A PTU (Power Transfer Unit) enables:
✅ The YELLOW system to pressurize the GREEN system and vice versa
- QADCC1 variant
The hydraulic reservoirs are pressurized:
✅ By high pressure bleed air from engine number one or, if insufficient, by bleed air from the cross bleed duct
- QNCFU1 variant
If the green system is lost, flap operation is: