Oxygen
- QSFPA1 variant
Emergency Descent from FL370: Which statement is correct?
✅ With the N/100% selector to NORMAL the mask provides the flight crew with a mixture of air and oxygen. This mixture changes with cabin altitude. The higher the cabin altitude, the more oxygen the mask provides until the mask supplies 100% oxygen
- QUVOT1 variant
If the N/100% regulator is set to "N", it delivers a mixture of air and oxygen to the mask, the content of which varies with cabin altitude. When cabin altitude goes _________, the air inlet closes and the wearer breathes 100 % oxygen.
✅ Above 35000 feet
- QDMQV1 variant
The minimum bottle pressure of the cockpit fixed oxygen system takes the following into account:
✅ Protection in case of smoke, with 100 % oxygen: For all cockpit members for 15 min at a cabin altitude of 8'000 ft
- QYJQZ1 variant
When does the flight crew have to use the oxygen masks?
✅ All answers are correct
- QNPTI1 variant
What is the last point of the oxygen mask test?
✅ No REGUL LO PR message on the ECAM page
- QAFHK1 variant
Oxygen system (cockpit): on ECAM DOOR/OXY page, CKPT OXY indication is normally green. It becomes amber when:
✅ All answers are correct
- QPTGA1 variant
OXYGEN STOWAGE BOX: As soon as the left flap door opens, the mask is supplied with oxygen and, once it closes (mask still supplied with oxygen), the ____ flag appears.
✅ OXY ON
- QHVUF1 variant
FIXED OXYGEN SYSTEM FOR CABIN - The generation of oxygen begins when the passenger pulls the mask towards the passenger seat. The mask receives pure oxygen under positive pressure for about ___ min, until the generator is exhausted
✅ 15 min
- QPPNS1 variant
FIXED OXYGEN SYSTEM FOR CABIN - Each container has an electrical latching mechanism that opens automatically to allow the masks to drop if:
✅ The cabin pressure altitude exceeds 14 000 ft (+ 250, - 750 ft). The flight crew can override the automatic control
- QNZZM1 variant
What measuring unit is used to depict the cockpit oxygen system pressure on the ECAM?
✅ PSI
- QJVXY1 variant
What can be done in order to relase a cabin oxygen mask, when the door fails to open?
✅ The Manual Release Tool (MRT) can be used by cabin crew to open affected containers
- QTCXL1 variant
What is indicated by a missing green pressure plug on the right fwd fuselage below F/O window during an exterior preflight check?
✅ An oxygen system overpressure or thermal discharge
- QGAGW1 variant
The illumination of the PASSENGER SYS ON light is an indication that:
✅ The control for the oxygen mask doors is activated
- QUFHZ1 variant
With reference to the OXY high pressure indication, which of the following is wrong?
✅ On ground, an amber half frame appears when oxygen pressure is < 1100 PSI
- QZVRE1 variant
FIXED OXYGEN SYSTEM FOR CABIN. Which statement is correct?
✅ Supplies oxygen for cabin occupants in case of depressurization only
- QAGWT1 variant
When is the FCM oxygen mask supplied with oxygen?
✅ As soon as the left flap door of mask container is opened
- QNCUC1 variant
FIXED OXYGEN SYSTEM FOR COCKPIT. Which statement about the EMERGENCY pressure selector is correct?
✅ Overpressure supply is only available when the N/100% selector is set to 100% and will be automatically started, when the cabin altitude exceeds 30,000 ft
- QKIVY1 variant
What does the PASSENGER SYS ON light mean?
✅ This light comes on white, when the control for the oxygen mask door is activated.
- QWUOI1 variant
When stowing the crew oxygen mask, when will the integrated microphone be deactivated automatically?
✅ After closing the left flap of the oxygen mask door and having presed the RESET button
- QLOCW1 variant
If the oxygen masks fail to deploy automatically how else can they be deployed?
✅ They can be deployed by pressing the MASK MAN ON pb on the overhead panel.
- QQRMK1 variant
On the ECAM DOOR/OXY page, the OXY indication becomes amber when: (more than one answer is correct)
✅ All answers are correct.
- QVZDX1 variant
The flight crew can not override the automatic control of the cabin oxygen system.
✅ False
- QDNKJ1 variant
OVHD Panel: The PASSENGER SYS ON light comes on ________ when the control for the oxygen mask doors is activated.
✅ White
- QIJKJ1 variant
The oxygen system consists of:
✅ All answers are correct.
- QDUWC1 variant
Fixed oxygen system cabin: Each chemical generator container has an electrical latching mechanism that opens automatically to allow the masks to drop, if the cabin pressure altitude exceeds ________________________.
✅ 14000 feet (+ 250, - 750)