Air Systems
- QFEEH2 variants
When operating on the standby pack controls, what temperature do the packs produce?
✅ The average temperature demand of the two passenger cabin zones.
- QOMUS2 variants
If all Temperature Selectors are positioned OFF, which fixed temperatures do the packs produce?
✅ Left pack 24°C, right pack 18°C.
- QNTJV1 variant
Which systems rely on the bleed air system?
✅ Air conditioning and pressurisation, wing and engine anti-ice, engine starting, hydraulic reservoir pressurisation, water tank pressurisation.
- QQHMB4 variants
Pushing the TRIP RESET switch resets a BLEED TRIP OFF light and opens the related engine bleed air valve.
✅ True
- QVBXL2 variants
The APU can supply bleed air for two packs on the ground, or one pack in flight.
✅ True
- QCXMW2 variants
The engine bleed air valve acts as both a pressure regulator and a shutoff valve.
✅ True
- QUDEO2 variants
Engine bleed air is obtained from the 5th and 9th stages of the compressor section.
✅ True
- QKFTD1 variant
When is engine bleed air taken from the 9th stage?
✅ Only when 5th stage bleed air is insufficient and the high stage valve modulates open.
- QZZRQ2 variants
With the ISOLATION VALVE switch in AUTO, when is the isolation valve closed?
✅ When both engine BLEED air switches are ON and both PACK switches are AUTO or HIGH.
- QGLLH2 variants
What is the function of the DUAL BLEED light?
✅ It illuminates when the APU bleed air valve is open and the engine bleed air switches and isolation valve would permit possible backpressure of the APU.
- QEGAM1 variant
Which condition illuminates the amber DUAL BLEED light?
✅ APU bleed air valve open and engine No. 1 BLEED air switch ON.
- QMRLH1 variant
What does the BLEED TRIP OFF light indicate?
✅ Excessive engine bleed air temperature or pressure; the related engine bleed air valve has closed automatically.
- QQWLB1 variant
Where are the wing-body overheat sensors located?
✅ Engine struts, inboard wing leading edges, air conditioning bays, APU bleed duct, keel beam.
- QIFHB2 variants
Which wing-body overheat light illuminates for a leak in the APU bleed air duct?
✅ The left WING-BODY OVERHEAT light.
- QAYFW1 variant
How many trim air modulating valves are there?
✅ Three, one for each zone.
- QDQCB2 variants
The packs produce the air temperature required by the zone that needs the most cooling, and trim air warms the other zones.
✅ True
- QDGCB2 variants
A flight deck zone temperature control fails. What happens?
✅ Control switches automatically to the backup controller and the CONT CAB ZONE TEMP light illuminates on Master Caution Recall.
- QZUHX2 variants
What happens if the primary pack control of one pack fails?
✅ The pack is controlled by the standby pack control in the opposite controller.
- QWYYZ2 variants
Both PACK switches are AUTO and one pack fails in flight with the flaps up. What flow does the remaining pack deliver?
✅ High flow, selected automatically.
- QPWCG1 variant
What is the primary function of the recirculation fans?
✅ Reduce the load on the packs and the engine bleed air demand.
- QZNFD3 variants
Conditioned air from the left pack flows directly to the flight deck, upstream of the mix manifold.
✅ True
- QITUR1 variant
The differential pressure of the cabin is limited by a pressure relief system. Which statement is correct?
✅ Two pressure relief valves limit the differential pressure to 9.1 psi.
- QBOTX1 variant
With the pressurisation in MANUAL during descent and the outflow valve still closed or partially closed, what misleading indication might the CABIN ALT gauge show?
✅ The needle may continue anti-clockwise past zero and point to a high cabin altitude.
- QJRXW1 variant
In MANUAL pressurisation mode, what position should the outflow valve be in on landing?
✅ Fully open.
- QQJPP3 variants
What does the ALT HORN CUTOUT switch do?
✅ It silences the intermittent cabin altitude warning horn.
- QXNHW2 variants
Cabin air outflow is controlled by the outflow valve and the overboard exhaust valve, and a small amount leaves through toilet and galley vents.
✅ True