Electrical
- QEIZH1 variant
Which of the following is NOT powered by the standby Power system?
✅ Transformer Rectifier 1.
- QLZQO1 variant
What is the normal source of power for the Battery Bus?
✅ TR3
- QSFGD1 variant
The DC standby Bus is powered from the batteries through the static Inverter. Select one:
✅ False
- QTNJC1 variant
What is the voltage of the DC Busses under normal circumstances?
✅ 28v
- QAAOZ1 variant
If all AC generated power fails, how long can the batteries (if fully charged) supply standby power?
✅ A minimum of 60 minutes.
- QPIVO1 variant
If an IDG fails and the APU is not available to power the related Transfer Bus, what occurs first if an electrical overload is sensed?
✅ Automatic load shedding of the galleys and main bus on Transfer Bus 2
- QDPWU1 variant
With the BUS TRANSFER switch in the AUTO position; how do the BTBs operate?
✅ BTBs automatically maintain power to AC Transfer busses from any operating generator or external power.
- QNUQN1 variant
Which bus(ses) will be automatically shed if the APU is the only source of electrical power in flight?
✅ All galley and main busses
- QLSGH2 variants
The amber TR UNIT light illuminated while in-flight indicates if?
✅ TR1 has failed, or TR2 and TR3 have failed.
- QSQHV2 variants
The amber TR UNIT light illuminated while on the ground indicates if?
✅ One TR has failed.
- QDNKS1 variant
The Static Inverter, converts the Battery's 22-30V DC voltage range to a constant 24V.
✅ False
- QCXUI1 variant
Under what conditions are DC bus 1 and DC bus 2 isolated.
✅ All the other answers are true.
- QVZMK1 variant
When external ground power is connected to the aircraft through the External AC Receptacle, the GRD POWER AVAILABLE light does not illuminate unless the power supplied meets the quality requirements of 115v AC, 200 Hz, 3 phase.
✅ False
- QAMNO1 variant
An illuminated amber ELEC light on the AC and DC Metering Panel indicates?
✅ A fault exists in the DC power system or the Standby power system
- QYWZS1 variant
With the STANDBY POWER switch (located on the Generator Drive and Standby Power Panel) in the AUTO position, will the loss of a single DC Bus result in automatic switching from normal to alternate power?
✅ Only if power from DC Bus 1 is lost
- QYOLU1 variant
Which electrical bus is always connected and powered whenever the aircraft battery is fitted?
✅ Hot Battery Bus - power immediately available to important systems such as fire extinguishers.
- QFBIQ1 variant
Why are the covers on the Drive DISCONNECT switches red?
✅ To identify switch action is irreversible in flight.
- QXBKZ1 variant
If the APU is powering Transfer Bus 1 and GEN 2 is powering Transfer Bus 2, what will occur when the Ground Power (GRD PWR) Switch is turned to ON?
✅ Ground Power will power both Transfer Busses. The SOURCE OFF lights will remain extinguished.
- QBAUT1 variant
What is the normal source of power for the DC Standby bus?
✅ TR1, TR2 and TR3
- QCKVH1 variant
What is the purpose of the Ground Service switch on the forward attendant's panel?
✅ Provides ground power directly to the AC ground services bus for utility outlets, cabin lighting, and battery charger without powering all aircraft electrical busses.
- QVAPI1 variant
What is the normal AC power source for TR3?
✅ Transfer Bus 2
- QTDUP1 variant
What is the effect of selecting the Drive Disconnect switch to DISCONNECT?
✅ IDG is disconnected if running, and DRIVE light illuminates.
- QZJXJ1 variant
What is the source of power for the AC Standby bus if all AC power is lost.
✅ The Static Inverter
- QFQXT1 variant
The main battery charger is powered by?
✅ AC Ground Service Bus 2
- QPVYL1 variant
The 2 basic rules of the B737-800 electrical system are: Only one AC power source can be connected at one time. A second source connecting to a transfer bus will automatically disconnect the existing source.
✅ True
- QFBJF1 variant
What indications will you see on the electrical panel when selecting GRD PWR ON?
✅ GRD POWER AVAILABLE light illuminated, SOURCE OFF lights extinguished, GEN OFF BUS lights illuminated, TRANSFER BUS OFF lights extinguished, APU GEN OFF BUS light extinguished.
- QEBDR1 variant
If operating on a single IDG and an overload is sensed, the electrical system will shed the galleys and main bus from Transfer Bus 1 and then Transfer Bus 2 before then shedding the IFE busses if an overload is still sensed.
✅ False
- QYVMB1 variant
Under normal conditions, what powers DC Bus 1?
✅ TR1 and TR2
- QTLJM1 variant
Which air conditioning system will not operate unless the CAB/UTIL switch is ON?
✅ Left & right Recirculation fans
- QCULN1 variant
How is the auxiliary battery charger powered?
✅ Through the AC Ground Service Bus
- QQENL1 variant
With the STANDBY POWER switch (located on the Generator Drive and Standby Power Panel) in the AUTO position, will the loss of a single AC Transfer Bus result in automatic switching from normal to alternate power?
✅ Only if power from AC Transfer Bus 1 is lost
- QRORI1 variant
In the event of the loss of all engine and APU IDGs, the Standby Power system will provide what electrical power?
✅ 115V AC and 24V DC
- QAKFD1 variant
If Ground power is powering both Transfer Busses, the APU is available, and is selected to power Transfer Bus 1, which statement is correct?
✅ Ground power will be automatically disconnected and the APU will power both Transfer Busses.
- QSTPD1 variant
What is the normal source of power for the AC Standby Bus?
✅ AC Transfer Bus 1
- QJDDD1 variant
The SOURCE OFF light illuminates whenever an IDG has tripped offline due to overheating.
✅ False
- QAIKF1 variant
Maintaining uninterrupted power on both AC Transfer Busses is primarily the function of:
✅ The Bus Tie Breakers (BTBs)
- QOANL1 variant
With the BUS TRANSFER switch in AUTO, if one IDG fails in flight, what happens next?
✅ The generator circuit breaker on the failed side opens, bus tie breakers 1 and 2 close and both AC transfer buses are powered by the remaining IDG.
- QWYKG1 variant
If the TR UNIT light illuminates in flight, why should you not use the AFDS approach mode on an ILS approach?
✅ On glideslope capture the cross bus tie relay opens, which leaves part of the DC system without power.
- QWMFA1 variant
If a GEN OFF BUS light illuminates in flight, what may occur as an indirect consequence?
✅ If the autopilot is engaged on the affected side, it may disconnect due to the momentary loss of power.
- QWCOY1 variant
Which of these conditions would cause an IDG DRIVE light to illuminate in flight?
✅ IDG low oil pressure.
- QAMTL1 variant
After a normal engine start, what indication shows that GEN 1 has connected successfully when selected to ON?
✅ The related blue GEN OFF BUS light extinguishes.
- QIZIP1 variant
When ground power is available and selected ON, which AC transfer buses are powered?
✅ AC transfer bus 1 and AC transfer bus 2.